No information provided.
At present there are no known contraindications to the use of the SynVet-50 OVD when used as recommended.
The SynVet-50 OVD is extremely well tolerated after injection into human eyes. A transient rise of intraocular pressure postoperatively has been reported in some cases.
In posterior segment surgery intraocular pressure rises have been reported in some patients, especially in aphakic diabetics, after injection of large amounts of the SynVet-50 OVD.
Rarely, postoperative inflammatory reactions (iritis, hypopyon) as well as incidents of corneal edema and corneal decompensation have been reported. Their relationship to the SynVet-50 OVD has not been established.
The SynVet-50 OVD is indicated for use as a surgical aid in cataract extraction (intra- and extracapsular), IOL implantation, corneal transplant, glaucoma filtration and retinal attachment surgery.
In surgical procedures in the anterior segment of the eye, instillation of the SynVet-50 OVD serves to maintain a deep anterior chamber during surgery, allowing for efficient manipulation with less trauma to the corneal endothelium and other surrounding tissues.
Furthermore, its viscoelasticity helps to push back the vitreous face and prevent formation of a postoperative flat chamber.
In posterior segment surgery the SynVet-50 OVD serves as a surgical aid to gently separate, maneuver and hold tissues.The SynVet-50 OVD creates a clear field of vision thereby facilitating intra- and post-operative inspection of the retina and photocoagulation.
Included as part of the PRECAUTIONS section.
PRECAUTIONSThose normally associated with the surgical procedure being performed.
Overfilling the anterior or posterior segment of the eye with the SynVet-50 OVD may cause increased intraocular pressure, glaucoma, or other ocular damage.
Postoperative intraocular pressure may also be elevated as a result of preexisting glaucoma, compromised outflow and by operative procedures and sequelae thereto, including enzymatic zonulysis, absence of an iridectomy, trauma to filtration structures, and by blood and lenticular remnants in the anterior chamber. Since the exact role of these factors is difficult to predict in any individual case, the following precautions are recommended:
Care should be taken to avoid trapping air bubbles behind the SynVet-50 OVD.
Because the SynVet-50 OVD is a highly purified fraction extracted from avian tissues and is known to contain minute amounts of protein, the physician should be aware of potential risks of the type that can occur with the injection of any biological material.
Because of reports of an occasional release of minute rubber particles, presumably formed when the diaphragm is punctured, the physician should be aware of this potential problem. Express a small amount of the SynVet-50 OVD from the syringe prior to use, and carefully examine the remainder as it is injected.
Reprocessed cannulas should not be used.
Sporadic reports have been received indicating that the SynVet-50 OVD may become ”cloudy” or form a slight precipitate following instillation into the eye.The clinical significance of these reports, if any, is not known since the majority received to date do not indicate any harmful effects on ocular tissues.The physician should be aware of this phenomenon and, should it be observed, remove the cloudy or precipitated material by irrigation and/or aspiration.
In vitro laboratory studies suggest that this phenomenon may be related to interactions with certain concomitantly administered ophthalmic medications.
Use only if solution is clear.
A sufficient amount of the SynVet-50 OVD is slowly, and carefully introduced (using a cannula or needle) into the anterior chamber.
Injection of the SynVet-50 OVD can be performed either before or after delivery of the lens. Injection prior to lens delivery will, however, have the additional advantage of protecting the corneal endothelium from possible damage arising from the removal of the cataractous lens5.The SynVet-50 OVD may also be used to coat surgical instruments and the IOL prior to insertion.
Additional SynVet-50 OVD can be injected during surgery to replace any SynVet-50 OVD lost during surgical manipulation (see PRECAUTIONS section).
Glaucoma Filtration SurgeryIn conjunction with performing of the trabeculectomy, the SynVet-50 OVD is injected slowly and carefully through a corneal paracentesis to reconstitute the anterior chamber. Further injection of the SynVet-50 OVD can be continued allowing it to extrude into the subconjunctival filtration site and through and around the sutured outer scleral flap.
Corneal Transplant SurgeryAfter removal of the corneal button, the anterior chamber is filled with the SynVet-50 OVD.The donor graft can then be placed on top of the bed of SynVet-50 OVD and sutured in place.Additional SynVet-50 OVD may be injected to replace the SynVet-50 OVD lost as a result of surgical manipulation (see PRECAUTIONS section).The SynVet-50 OVD has also been used in the anterior chamber of the donor eye prior to trepanation to protect the corneal endothelial cells of the graft5.
Retinal Attachment SurgeryThe SynVet-50 OVD is slowly introduced into the vitreous cavity. By directing the injection, the SynVet-50 OVD can be used to separate membranes (e.g. epiretinal membranes) away from the retina for safe excision and release of traction.The SynVet-50 OVD also serves to maneuver tissues into the desired position, e.g. to gently push back a detached retina or unroll a retinal flap, and aids in holding the retina against the sclera for reattachment.
Instructions Sterile Opening TechniqueTear off the paper covering.
Bend the plastic backwards at the central indentation so as to fully expose the white plastic rod.
Dislodge syringe and place onto sterile field.
Press the vial completely into the holder so that the needle perforates the membrane.
ImportantPerforate the membrane before screwing on the plastic rod.
Remove the plastic rod.
Screw the plastic rod into the blue plunger.
Connect the cannula and check for proper function.
Store at 2 to 8°C (36 to 46°F). For single use only