Luminity

Top 20 drugs with the same components:

Overdose

The clinical consequences of overdose with Luminity are not known. Single doses of up to 100 microlitres dispersion/kg and multiple doses up to 150 microlitres dispersion/kg were tolerated well in Phase I clinical trials. Treatment of an overdose should be directed towards the support of all vital functions and prompt institution of symptomatic therapy.

Shelf life

2 years.

The product should be used within 12 hours of activation. The product can be re-activated up to 48 hours after initial activation and used up to 12 hours after the second activation.

After activation: Do not store above 30°C.

List of excipients

1,2-dipalmitoyl-sn-glycero-3-phosphatidylcholine (DPPC)

1,2-dipalmitoyl-sn-glycero-3-phosphatidic acid, monosodium salt (DPPA)

N-(methoxypolyethylene glycol 5000 carbamoyl)-1,2-dipalmitoyl-sn-glycero-3- phosphatidylethanolamine, monosodium salt (MPEG5000 DPPE)

Sodium dihydrogen phosphate monohydrate

Disodium hydrogen phosphate heptahydrate

Sodium chloride

Propylene glycol

Glycerol

Water for injections

Pharmaceutical form

Gas and solvent for dispersion for injection/infusion

Colourless, uniformly clear to translucent liquid.

Undesirable effects

Summary of the safety profile

The reported adverse reactions following the use of Luminity in pivotal and supportive trials (total of 2,526 patients) occur within minutes after administration and usually resolve without therapeutic intervention within 15 minutes. The most frequently reported adverse reactions are: headache (2.0%), flushing (1.0%) and back pain (0.9%).

Tabulated list of adverse reactions

Adverse reactions were reported with the following frequencies (Very common > 1/10; Common > 1/100 to < 1/10; Uncommon > 1/1,000 to < 1/100; Rare > 1/10,000 to < 1/1,000; Very rare < 1/10,000), not known (cannot be estimated from the available data). Within each frequency grouping, adverse reactions are presented in order of decreasing seriousness.

Immune system disorders

Not known: Allergic type reactions, anaphylaxis, anaphylactic shock and anaphylactoid type reactions, hypotension, angioedema, lip swelling, bronchospasm, rhinitis, upper airway swelling, throat tightness, facial swelling, eye swelling

Nervous system disorders

Common: Headache

Uncommon: Dizziness, dysgeusia

Rare: Paraesthesia

Not known: seizures, facial hypoaesthesia, loss of consciousness

Eye disorders

Not known: Abnormal vision

Cardiac disorders

Rare: Bradycardia, Tachycardia, Palpitations

Not known: Cardiac arrest, ventricular arrhythmias (ventricular fibrillation, ventricular tachycardia, premature ventricular contactions), asystole, atrial fibrillation, cardiac ischaemia, supraventricular tachycardia, supraventricular arrhythmia

Vascular disorders

Common: Flushing

Uncommon: Hypotension

Rare: Syncope, hypertension, peripheral coldness

Respiratory, thoracic and mediastinal disorders

Uncommon: Dyspnoea, Throat Irritation

Rare: Respiratory Distress, Cough, Dry Throat

Not known: Respiratory arrest, decreased oxygenation, hypoxia,

Gastrointestinal disorders

Uncommon: Abdominal Pain, diarrhoea, nausea, vomiting,

Rare: Dyspepsia

Not known: Tongue disorder

Skin and subcutaneous tissue disorders

Uncommon: Pruritus, increased sweating

Rare: Rash, urticaria, erythema, erythematous rash

Musculoskeletal and connective tissue disorders

Uncommon: Back pain

Rare: Arthralgia, flank pain, neck pain, muscle cramp

Not known: Muscle spasm, musculoskeletal pain, musculoskeletal discomfort, myalgia, hypertonia

General disorders and administration site conditions

Uncommon: Chest Pain, fatigue, feeling hot, injection site pain

Rare: Pyrexia, rigors

Investigations

Rare: Abnormal electrocardiogram

Reporting of suspected adverse reactions

Reporting suspected adverse reactions after authorisation of the medicinal product is important. It allows continued monitoring of the benefit/risk balance of the medicinal product. Healthcare professionals are asked to report any suspected adverse reactions via the national reporting system.

Yellow Card Scheme

Website: www.mhra.gov.uk/yellowcard

Preclinical safety data

Preclinical data reveal no special hazard for humans based on conventional studies of genotoxicity, fertility, embryo/foetal development, parturition or post-natal development, and local tolerance.

Abnormal respiration, heart rate changes and decreased activity were observed soon after intravenous injection of Luminity at doses > 0.3 ml/kg in single and repeat-dose toxicity studies in rats and monkeys. Higher doses of the product, typically > 1 ml/kg, resulted in more severe signs including unresponsiveness and occasionally death. These levels are substantially above the recommended maximal clinical dose. Rats treated with Luminity for 1 month exhibited dose-related, reversible perivascular and peribronchiolar eosinophil infiltration, alveolar macrophage accumulation and increased goblet cell size and number in the lungs. These effects were observed at exposure levels in excess of the maximum human exposure indicating little relevance to clinical use.

Therapeutic indications

This medicinal product is for diagnostic use only.

Luminity is an ultrasound contrast-enhancing agent for use in adult patients in whom non-contrast echocardiography was suboptimal (suboptimal is considered to indicate that at least two of six segments in the 4- or 2-chamber view of the ventricular border were not evaluable) and who have suspected or established coronary artery disease, to provide opacification of cardiac chambers and improvement of left ventricular endocardial border delineation at both rest and stress.

Pharmacotherapeutic group

ultrasound contrast media, microspheres of phospholipids, ATC Code: V08DA04

Pharmacodynamic properties

Pharmacotherapeutic group: ultrasound contrast media, microspheres of phospholipids, ATC Code: V08DA04

The product consists of lipid encapsulated perflutren microspheres. Microspheres in the 1 to < 10 µm diameter size range contribute to the contrast effect by generating strongly enhanced echoes.

The ultrasound echoes from blood and biological soft tissues such as fat and muscles are generated at interfaces due to small differences in the ultrasonic properties of the tissues. The ultrasonic properties of the product are very different from those of soft tissue and will generate strong echoes.

As Luminity consists of microspheres that are stable and small enough for transpulmonary passage, enhanced echo signals in the left heart and systemic circulation are obtained.

A strict dose/response relationship cannot be defined, although higher doses have been shown to produce a contrast effect of longer duration.

Pharmacokinetic properties

The pharmacokinetic properties of Luminity were evaluated in normal healthy subjects and subjects with chronic obstructive pulmonary disease (COPD) following intravenous administration of a 50 µl/kg dose of the product.

The perflutren component of Luminity was rapidly cleared from the systemic circulation via the lungs. The percentage of the perflutren dose excreted in expired air was approximately 50% of the administered dose due to the small quantities of perflutren given and the inability to quantify low levels of perflutren by gas chromatography. In most subjects after 4-5 minutes, perflutren was undetectable in blood and expired air. Perflutren concentrations in blood were shown to decline in a mono-exponential fashion with a mean half-life of 1.3 minutes in healthy subjects and 1.9 minutes in COPD subjects. The systemic clearance of perflutren was similar in healthy and COPD subjects. Total lung clearance (CLlung) of perflutren was shown to be no different in healthy subjects compared to COPD subjects. CLlung was found to be significantly reduced (51%) in females compared to males (all subjects). These results suggest that overall perflutren systemic elimination is rapid and is not significantly reduced in COPD patients compared to healthy subjects. Doppler ultrasound measurements were performed with Luminity in conjunction with the pharmacokinetic evaluation of perflutren. Doppler signal intensity corresponded well with measured and extrapolated perflutren concentrations in blood. The time to maximum Doppler signal intensity tmax was shown to be similar to the perflutren blood tmax (1.13 versus 1.77 minutes). The observed 99% drop in Doppler signal intensity within 10 minutes (t1/2 approximately 2 minutes) was in agreement with the decline in measurable blood levels of perflutren.

Fundamental and non-linear imaging techniques (second harmonic, multipulse phase and/or amplitude modulation) using both continuous and triggered acquisition were utilised in clinical studies with Luminity.

The naturally occurring phospholipids in Luminity are distributed in the endogenous lipid pools in the body (for example, liver) whereas the synthetic component (MPEG5000) has been shown to be excreted in the urine in preclinical studies. All lipids are metabolised to free fatty acids. The pharmacokinetics and metabolism of MPEG5000 DPPE have not been evaluated in humans.

Pharmacokinetics in special population groups

Elderly

Pharmacokinetics has not been specifically studied in the elderly.

Renal impairment

Pharmacokinetics has not been specifically studied in the renal disease patients.

Hepatic impairment

Pharmacokinetics has not been specifically studied in the hepatic disease patients.

Date of revision of the text

July 2016

Name of the medicinal product

Luminity 150 microlitres/ml gas and solvent for dispersion for injection/infusion

Marketing authorisation holder

Lantheus MI UK Limited

Festival House

39 Oxford Street

Newbury, Berkshire, RG14 1JG

United Kingdom

Special precautions for storage

Store in a refrigerator (2°C - 8°C)

Nature and contents of container

1.5 ml liquid in clear borosilicate Type I glass vial, closed with a chlorobutyl elastomeric lyophilisation stopper, and sealed with an aluminium crimp seal having a plastic flip-off button.

Pack sizes of 1 or 4 vials.

Not all pack sizes may be marketed.

Marketing authorisation number(s)

EU/1/06/361/001 - 002

Fertility, pregnancy and lactation

Pregnancy

For perflutren, no clinical data on exposed pregnancies are available. Animal studies do not indicate direct or indirect harmful effects with respect to pregnancy, embryonal/foetal development, parturition or postnatal development. Caution should be exercised when prescribing to pregnant women.

Breast-feeding

It is not known whether Luminity is excreted in human breast milk. Therefore, caution should be exercised when Luminity is administered to breast-feeding women.

Fertility

Animal studies do not indicate direct or indirect harmful effects on fertility.

Qualitative and quantitative composition

Each ml contains a maximum of 6.4 x 109 perflutren-containing lipid microspheres, with a mean diameter range of 1.1-2.5 micrometres (μm). The approximate amount of perflutren gas in each ml is 150 microlitres (μl).

Excipient(s) with known effect

Each ml contains 2.679 mg sodium

Special warnings and precautions for use

This product must only be administered intravenously.

Luminity should not be used with fundamental imaging technique for stress echocardiography since efficacy and safety have not been established.

Patients with unstable cardiopulmonary status

During contrast-enhanced echocardiography, serious cardiopulmonary reactions, including fatalities, have occurred during or within 30 minutes of Luminity administration in patients including those with severe cardiac and pulmonary diseases. Extreme caution should be used when considering the administration of Luminity to patients with unstable cardiopulmonary status, for example: unstable angina, acute myocardial infarction, severe ventricular arrhythmias, severe heart failure (NYHA IV) or respiratory failure. Luminity should only be administered to such patients after careful risk/benefit assessment.

Contrast-enhanced echocardiography should only be considered in such patients if the results are likely to produce a change in individual patient management.

Patients with unstable cardiopulmonary status should be monitored during and for at least 30 minutes following Luminity administration. For such patients monitoring should include vital sign measurements, electrocardiography, and, if clinically appropriate, cutaneous oxygen saturation. Resuscitation equipment and trained personnel must always be readily available.

Patients with adult respiratory distress syndrome, endocarditis, prosthetic heart valves, systemic inflammation, sepsis, hyperactive coagulation and/or recurrent thromboembolism

Luminity should be used only after careful consideration and such use should be monitored closely during administration in patients with adult respiratory distress syndrome, endocarditis, a heart with prosthetic valves, acute states of systemic inflammation or sepsis, known states of hyperactive coagulation and/or recurrent thromboembolism.

Hypersensitivity reactions

Serious immediate hypersensitivity reactions (eg: anaphylaxis, anaphylactic shock and anaphylactoid reactions, hypotension and angioedema) have been reported following the administration of Luminity. Patients should be closely monitored and administration should be under the direction of a physician experienced in the management of hypersensitivity reactions including severe allergic reactions, which might require resuscitation. Emergency equipment and personnel trained in its use must be readily available.

Pulmonary disease

Caution should be exercised in patients with clinically significant pulmonary disease, including diffuse interstitial pulmonary fibrosis and severe chronic obstructive pulmonary disease, as no studies have been performed in these patients.

Patients with Cardiac Shunts

The safety of Luminity in patients with right-to-left, bi-directional or transient right-to-left cardiac shunts has not been studied. In these patients, phospholipid encapsulated microspheres can bypass the lung and directly enter the arterial circulation. Caution must be exercised when considering the administration of Luminity to these patients.

Patients on mechanical ventilation

The safety of microspheres in patients on mechanical ventilation has not been established. Caution should be exercised when considering the administration of Luminity to these patients.

Administration and mechanical activation procedure

(e.g. intra-arterial injection).

If Luminity is administered directly to the patient without undergoing the mechanical activation procedure using the Vialmix , the product will not produce its intended effect.

Sodium Content

This medicinal product contains less than 1 mmol sodium (23 mg) per dose, i.e. essentially 'sodium- free'

Effects on ability to drive and use machines

As Luminity has no pharmacologic effect, and on the basis of its pharmacokinetic and pharmacodynamic profiles, no or negligible influence is expected with the use of this product on the ability to drive or use machines.

Dosage (Posology) and method of administration

Luminity should only be administered by trained physicians with technical expertise in performing and interpreting contrast echocardiograms, and appropriate resuscitation equipment should be available in case of cardiopulmonary or hypersensitivity reactions.

Posology

Bolus intravenous injection using non-linear contrast imaging technique at rest and stress:

The recommended dose is multiple injections of 0.1 to 0.4 ml of dispersion, followed by a 3 to 5 ml bolus of sodium chloride 9 mg/ml (0.9%) or glucose 50 mg/ml (5%) solution for injection to maintain optimal contrast enhancement. The total dose of perflutren should not exceed 1.6 ml.

Bolus intravenous injection using fundamental imaging technique at rest:

The recommended dose is 10 microlitre dispersion/kg by slow bolus intravenous injection, followed by a 10 ml bolus of sodium chloride 9 mg/ml (0.9%) or glucose 50 mg/ml (5%) solution for injection. If necessary, a second 10 microlitre dispersion/kg dose followed by a second 10 ml bolus of sodium chloride 9 mg/ml (0.9%) or glucose 50 mg/ml (5%) solution for injection may be administered 5 minutes after the first injection to prolong contrast enhancement.

Intravenous infusion using non-linear contrast imaging technique (rest and stress) or fundamental imaging technique at rest:

The recommended dose via an intravenous infusion is 1.3 ml dispersion added to 50 ml of sodium chloride 9 mg/ml (0.9%) or glucose 50 mg/ml (5%) solution for injection. The rate of infusion should be initiated at 4 ml/minute, but titrated as necessary to achieve optimal image enhancement, not to exceed 10 ml/minute.

Paediatric population

The safety and efficacy of Luminity in children and adolescents below 18 years have not been established. No data are available.

Patients with hepatic impairment

Luminity has not been specifically studied in patients with hepatic impairment. Use in this patient group should be on the basis of a benefit risk assessment by the physician.

Patients with renal impairment

Luminity has not been specifically studied in patients with renal impairment. Use in this patient group should be on the basis of a benefit risk assessment by the physician.

Elderly patients

Luminity has not been specifically studied in elderly patients. Use in this patient group should be on the basis of a benefit risk assessment by the physician.

Method of administration

Intravenous use.

Special precautions for disposal and other handling

It is essential to follow instructions for use and handling of Luminity and to adhere to strict aseptic procedures during preparation. Like all parenteral products, the vials must be inspected visually for particulates and vial integrity. Before administering the product, it must be activated by using the Vialmix, a mechanical shaking device. The Vialmix is not included in the Luminity pack but will be provided to healthcare professionals upon ordering the pack.

Luminity is activated by using the Vialmix which has a programmed shaking time of 45 seconds. The Vialmix will alert the operator if the shaking frequency varies by 5% or more below the target frequency. It also has been programmed to shut down and will provide visual and audio warnings if the shaking frequency exceeds the target frequency by 5%, or falls below the target frequency by 10%.

Activation process and administration

- The vial should be activated using the Vialmix. Immediately after activation, Luminity appears as a milky white dispersion.

Note: if the product is allowed to stand for more than 5 minutes after activation, it should be resuspended with 10 seconds of hand agitation prior to syringe withdrawal from the vial. Luminity should be used within 12 hours following activation. The product can be re-activated up to 48 hours after initial activation and used up to 12 hours after the second activation, whether stored under refrigeration or at room temperature. Do not store the vial above 30°C following activation.

- The vial should be vented with a sterile syringe needle or a sterile non-siliconised mini-spike before withdrawing the dispersion.

- The dispersion should be withdrawn from the vial using a syringe with a 18 to 20 gauge sterile needle or attached to a sterile non-siliconised mini-spike. When using a needle, it should be positioned to withdraw the material from the middle of the liquid in the inverted vial. No air should be injected into the vial. The product should be used immediately after its withdrawal from the vial.

- Luminity may be diluted with sodium chloride 9 mg/ml (0.9%) solution for injection or glucose 50 mg/ml (5%) solution for injection.

The contents of the vial are intended for single use only.

Any unused product or waste material should be disposed of in accordance with local requirements.

Date of first authorisation/renewal of the authorisation

Date of first authorisation: 20 September 2006

Date of latest renewal: 15 July 2016

Interaction with other medicinal products and other forms of interaction

No interaction studies have been performed and no other forms of interaction have been identified.